LED Spot RGBW Tree Gen. 1¶
- Knowledge Base
- Devices
- LED Spot RGBW Tree Gen. 1
The LED Spot RGBW Tree is a recessed LED spot with warm white and colored light for 24VDC supply. The connection to the Miniserver is via Loxone Tree technology.
Datasheet LED Spot RGBW Tree Gen. 1
Table of Contents¶
- Mounting
- Commissioning
- Tree Communication and Voltage Drop
- Inputs, Outputs, Properties
- Safety Instructions
- Documents
Mounting↑¶
Switch off the supply voltage before installation.
Connect the power supply (orange/white wire) and Tree communication wires (green/white wire).
Flip the spring clips back and snap the spotlight into the mounting hole. Make sure that no wires are jammed.

Commissioning↑¶
Then follow the pairing procedure on the Tree Interface.
Tree Communication and Voltage Drop↑¶
If the current flow on the GND line results in a voltage drop too high, this potential difference also affects the tree communication.
To solve this problem, split consumers of higher power over longer distances to several supply lines, or use a supply line with a higher cross-section, or a power supply close to the consumers.
For existing installations, doubling the cross-section of the GND line is often sufficient to eliminate the potential difference.
Actuators↑¶
| Summary | Description | Value Range |
|---|---|---|
| Smart actuator RGBW | Smart actuator | ∞ |
Diagnostic Inputs↑¶
| Summary | Description | Unit | Value Range |
|---|---|---|---|
| Online Status LED Spot RGBW Tree Gen. 1 | Indicates whether the device can be reached by the Miniserver. | Digital | 0/1 |
Properties↑¶
| Summary | Description | Default Value |
|---|---|---|
| Monitor online status | If checked, you will be notified via System Status or the Mailer if the device is no longer available or goes offline. | - |
| Serial number | Specifies the serial number of the device. | - |
| Actuator Type | Use device with Standard Actuator(s) or Smart Actuator(s) Smart Actuators support dynamic fade times and can only be used with the Lighting Controller. | - |
Safety Instructions↑¶
The installation must be carried out by a qualified technician in accordance with all applicable regulations.
Ensure that the device is protected from water.
Documents↑¶
Datasheet LED Spot RGBW Tree Gen. 1